| | Frequently Asked Questions: ANTARIS FAQTopic 3 | What are the requirements for a gyro to work with TIM-LR or SBR-LS? |
What are the requirements for a gyro to work with TIM-LR or SBR-LS?
Gyroscopes should at least meet the requirements below:
- Supply Voltage: 5.0V +/-0.25V
- Zero Point: 2.5V +/- 0.4V
- Scale factor: 25mV/°/s +/-5mV/°/s
- Dynamic Range: +/- 60°/s to +/- 125°/s
- Linearity: +/- 0.5% (Full Scale)
- Recommendated operating temp. range: -40 -to +85°C
Gyroscopes with a sensitivity (scale factor) lower than 20mV may work but the performance will be degraded. u-blox does not recommend using gyros with a lower sensitivity.
u-blox is currently aware of number of gyroscopes fulfilling these requirements (see list blow) but there might be others too.
- Bosch SMG066
- Kionix KGF01-075
- Melexis MLX90609-N2
- MuRata MEV-50A-R
- Panasonic EWTS86
- Epson XV-8000CB
|